Owner
Main P/N
AeroInfo P/N
End Item
AII P/N
Title
Douglas
27-M80-1218
27-M80-1218
1218
Simulator, Slat Actuator Drive. Powers Slat Actuators for functional test when stall warning computer is not installed.
Douglas
3774475
32-MUL-1097
-501
1097
Checker, Servo Valve. Assess the integrity of Servo Valve prior to removal from aircraft.
Douglas
3893555
30-D09-1493
-1
1493
Windshield Over/Under Temperature Detector Checker.
Douglas
3951738
27-M80-1517
1517
Gap, Target - Go-No-Go Gauges for proximity switches. Part of 5953920 for DC-9/MD80/MD90. Target gap used in conjunction with BITE on 717.
Douglas
3965776
21-MUL-1597
-1
1597
Sensor No-2, Cabin Temperature Tester. Flight line tester for cabin temperature control system. (Required for test, on MD-90 & 717. Must be used with 4751004-1, Cabin Temp Tester) (Superceded by 3965776-501)
Douglas
3965776
21-MUL-1597
-501
1597
Sensor No-2, Cabin Temperature Tester. Flight line tester for cabin temperature control system. (Required for test, on MD-90 & 717. Must be used with 4751004-1, Cabin Temp Tester). (supersedes 3965776-1)
Douglas
4750073
71-D08-1104
-501
1104
Tester, Engine Fire Detector, Portable. For troubleshooting Edison System (discrimination type).
Douglas
4751004
21-MUL-1062
-1
1062
Tester - Cabin Temperature. Flight line (ITCAN) test for cabin temperature control system. Has go/no go accuracy.
Douglas
4753880
28-MUL-1063
-1
1063
Line Checker, Fuel Flow System. Isolates malfunctioning components. For use with GE 12000 PPH indicators. Replaced by 4753880-503 Rev D.
Douglas
4753880
28-MUL-1063
-501
1063
Line Checker, Fuel Flow System. Isolates malfunctioning components. For use with GE 12000 PPH indicators. Designed for use on DC-8 and DC-9 with 12000 PPH indicators.
Douglas
4753880
28-MUL-1222
-503
1222
Line checker, Fuel Flow System. Isolate faulty components. Rev "D" for use on all DC-9 and MD80 using 12000 PPH and 16000 PPH indicators. Rev "D" used on airplanes with "Smith EDP". Tester can test wiring, power supplies, and transmitter only. The Smith p
Douglas
4753880
28-MUL-1222
-505
1222
Line checker, Fuel Flow System. Isolate faulty components. Rev "D" for use on all DC-9 and MD80 using 12000 PPH and 16000 PPH indicators. Rev "D" used on airplanes with "Smith EDP". Tester can test wiring, power supplies, and transmitter only. The Smith p
Douglas
4753880
28-MUL-1222
-507
1222
Line checker, Fuel Flow System. Isolate faulty components. Rev "D" for use on all DC-9 and MD80 using 12000 PPH and 16000 PPH indicators. Rev "D" used on airplanes with "Smith EDP". Tester can test wiring, power supplies, and transmitter only. The Smith p
Douglas
4753881
30-MUL-1064
-1
1064
Line Checker, Windshield Heater System. Used to troubleshoot and function check the anti-icing system. See application chart on drawing.
Douglas
4753881
30-MUL-1064
-501
1064
Line Checker, Windshield Heater System. Used to troubleshoot and function check the anti-icing system. See application chart on drawing.
Douglas
4753881
30-MUL-1064
-503
1064
Line Checker, Windshield Heater System. Used to troubleshoot and function check the anti-icing system. See application chart on drawing.
Douglas
4753881
30-MUL-1064
-505
1064
Line Checker, Windshield Heater System. Used to troubleshoot and function check the anti-icing system. See application chart on drawing.
Douglas
4753881
30-MUL-1064
-507
1064
Line Checker, Windshield Heater System. Used to troubleshoot and function check the anti-icing system. Not useable on DC-9 that requires the Over/Under Temperature Detector Checker. See -509 or application chart on drawing. Replaces -1, -501, -503, -505.
Douglas
4753881
30-MUL-1598
-509
1598
Line Checker, Windshield Heater System. Used to troubleshoot and function check the anti-icing system. Useable on DC-9 that requires the Over/Under Temperature Detector Checker, See application chart on drawing. Replaces 4753881-1, -501, -503, -505.
Douglas
4758059
77-MUL-1065
-1
1065
Engine Pressure Ratio Line Test Set. Troubleshoot transmitter & indicating system. (Engine operation is not required).
Douglas
4758059
77-MUL-1065
-501
1065
Engine Pressure Ratio Line Test Set. Troubleshoot transmitter & indicating system. (Engine operation is not required). 4758059-501 for DC-8
Douglas
4767451
28-D08-1094
1094
Line Checker, Fuel Flow System. Check or troubleshoot Consumed Fuel Indicating System. Special harnesses required for 70 series per Test Document. See 4753880-501
Douglas
4767452
71-D08-1165
1165
Line Check, Oil Quantity. Check and troubleshoot the Quantity and Low Level Indicating System.
Douglas
4767453
71-D08-1167
1167
Line Checker, Oil Cooler. Check and troubleshoot the Cooler Control System and components.
Douglas
4767454
71-D08-1163
-501
1163
Tester, Engine Pressure Ratio, Kollsman System. Engine synchronization system.
Douglas
4767457
21-D08-1126
1126
Line Checker, Cabin Temperature Control. Check/troubleshoot cockpit & cabin temperature control systems.
Douglas
4767458
71-D08-1101
1101
Tester, Engine Fire Detector, Portable. For troubleshooting original system (non-discrimination type).
Douglas
4767459
30-D08-1153
-1
1153
Windshield Heater System Line Test Set. Superceded by 4889798.
Douglas
4767460
30-D08-1153
-501
1153
Checker, De-Icing, Wing Slot/Tail System. Troubleshoot "One Shot" Tail De-Icing System.
Douglas
4767461
21-D08-1105
-1
1105
Analyzer, Cabin Pressurization System. Connects between aircraft system and amplifier.
Douglas
4770182
24-D08-1157
1157
Tester, Battery Ni-Cad. Applies calibrated load to battery to indicate 23 1/2 volt charge condition.
Douglas
4777255
32-D08-1095
-505
1095
Test Set, Anti-Skid System. Troubleshoot MK II System. (See 5916819-503).
Douglas
4777255
32-D08-1098
-507
1098
Test Set, Anti-Skid System. Troubleshoot MK III System and Spoilers. 70 series A/C with ASB 32-176 incorporated require special adapter for anti-skid. (Replaced by 5916819-503).
Douglas
4887411
30-D09-1066
-1
1066
Detector, Windshield Over/Under Temperature. Used for troubleshooting.
Douglas
4887411
30-D09-1066
-TJ
1066
Test Jig. Detector, Windshield Over/Under Temperature.
Douglas
4887886
71-D08-1096
1096
Tester, Engine Fire Detector, Portable. For troubleshooting Graviner System.
Douglas
4889798
30-D08-1166
1166
Line Checker, Windshield. To troubleshoot Heater System & components on eyebrow & clear-view windows.
Douglas
52-MUL-1204
52-MUL-1204
1204
Airstair, Power Panel Assembly. Adapts airstair to electric power, 28V in shop for testing operation of airstair.
Douglas
5763013
21-D08-1238
1238
Analyzer, Cabin Turbo-Compressor RPM Indicator. Troubleshoots indication, cabin control system & associated interlock and sensing systems. Portable.
Douglas
5766078
21-D08-1042
-505
1042
Analyzer, Refrigeration Freon System. Portable unit for troubleshooting system and the accuracy of freon controller.
Douglas
5767455
24-D08-1249
1249
Line Checker, Power Phase Sequence. Check and troubleshoot fuel pump (feed and boost). Radio rack blower, aft cargo compartment blower, lav pumps, cargo hoist, spoiler hyd pump, hor stab activator aux hyd pump.
Douglas
5916812
34-MUL-1089
-1
1089
Vertical Gyro Test Set. Simulate vertical gyro compass while performing test on various navigational systems.
Douglas
5916815
32-D09-1088
-1
1088
Tester, Brake Overheat Warning System & Components.
Douglas
5916816
22-MUL-1069
-501
1069
Test Set, Linear Servo Actuator. Adjustment & mechanical positioning of both servo actuators during rigging of the Mach Trim Compensator Actuator & Yaw Damper. Yaw damper test portion only is applicable to the 717.
Douglas
5916817
30-MUL-1067
-1
1067
Electric Thermal Switch Line Test Set. Check the five thermal switches, sensors & associated wiring. Use -501 for DC-9's with three thermal switches.
Douglas
5916817
30-MUL-1067
-501
1067
Electric Thermal Switch Line Test Set. Check the three thermal switches, sensors & associated wiring. Use -1 for DC-9's with five thermal switches.
Douglas
5916817
30-MUL-1067
-TJ
1067
Test Jig. Electric Thermal Switch. Used to test 5916817-1, -501.
Douglas
5916818
52-MUL-1068
-501
1068
Test Set, Airstair Assembly. To functionally operate and check out fwd passenger stairway on A/C or when positioned on rigging fixture.
Douglas
5916819
27-MUL-1070
-503
1070
Tester, Anti-Skid/Spoiler Control Box Line Test Set. Inject & monitor signals without disrupting the integrity of either system. (Anti-skid test only for DC-9 and DC-8, spoiler test for MD80, DC-9 and DC-8)
Douglas
5916819 (Test Panel)
27-MUL-1070
-TP
1070
Test Panel. Anti-Skid/Spoiler Control Box. Used with tester 5916819-503.
Douglas
5953600
34-MUL-1216
-1
1216
Simulator, Proximity Electronics Unit. Replaces proximity box & provides output signals to other systems so they can be exercised in all flight modes without moving A/C surfaces.
Douglas
5953920
34-MUL-1217
-1
1217
Proximity Switch Test Set. Tests Proximity Switch Electronics Unit
Douglas
5962510
29-MUL-1236
-1
1236
Tester, Auto Brake Control Box. Verifies proper function of valve solenoids and pressure switches.
Douglas
5963440
31-MUL-1227
-1
1227
CADC Remote Test Adapter. Used to remotely initiate CADC bite functions.
Douglas
5963442
31-M80-1233
-1
1233
Simulator, Autothrottle Speed Deviation. Used to simulate the autothrottle speed deviation signal to the flight data recorder.
Douglas
5963446
32-M90-1529
-1
1529
Test Set, Brake Valve and Bleed. To aid in brake bleeding and to troubleshoot the anti-skid manifolds. (MD-90's without autobrake).
Douglas
5963446
32-M90-1580
-501
1580
Test Set, Brake Valve and Bleed. To aid in brake bleeding and to troubleshoot the anti-skid manifolds. And the Autobrake Integrated Brake Control Valve (ICBVS) used on MD-90 with autobrake.
Douglas
5963448
49-M90-1530
-1
1530
Test Set, APU Inlet Door Actuator. For opening APU inlet doors without starting APU.
Douglas
5965698
32-M90-1589
-1
1589
Wedge - Brake Pedal Travel Switch Adjust.
Douglas
5965770
49-M90-1581
-1
1581
Test Set, Fault Indication - ENG/APU Generator. Tests wire integrity of ENG and APU Generator wire alerts. MRB requirement for engine and APU change.
Douglas
5965772
24-M90-1536
-1
1536
Test Set, Fault Indication - CONV/EPCU. Tests wire integrity of CONV Electronic Unit and EPCU Feeder Fault and EPCU Tie Lockout alerts. MRB requirement at 4C check.
Douglas
5965774
27-M90-1588
-1
1588
Indicator, Synchro Position. Elevator, rudder & horizontal stabilizer synchro position indicator. For the technician while aligning the synchro position transmitters.
Douglas
7951118PTE1
77-M80-1230
1230
N1 Speed Sensor Simulator. Simulates N1, N2, EPR, Automatic Reserve Thrust (ART) Solenoid & Follow-up Switch.
Douglas
7951118PTE2
31-M80-1232
1232
Flight Data Acquisition Unit (FDAU) Selector Box.
Douglas
CMM 27-80-07
27-M80-1439
1439
Proximity Sensor Test Set. Tests sensitivity of sensors.
Douglas
DZZ7174
32-D10-1446
-1
1446
Spinner, Anti-Skid Transducer. Used with P/N 32-MUL-1224.
Douglas
DZZ7218
52-MUL-1492
-1
1492
Set - Template, Door Switch Alignment, Down Limit.
Douglas
DZZ7355
26-MUL-1470
-1
1470
Leak Tester, Fire Extinguisher System. Pressure source for leak testing firex piping of engines & APU. Includes MD-11 pressure test adapters. supersedes T&E 26-20-02 Leak Tester. For DC-10, use with T&E 26-20-04 Adapter Kit.
Douglas
DZZ7355
26-MUL-1470
-501
1470
Leak Tester, Fire Extinguisher System. Pressure source for leak testing firex piping of engines & APU. Includes MD-11 pressure test adapters. supersedes T&E 26-20-02 Leak Tester. For DC-10, use with T&E 26-20-04 Adapter Kit.
Douglas
DZZ7355
26-MUL-1470
-503
1470
Leak Tester, Fire Extinguisher System. Pressure source for leak testing firex piping of engines & APU. Includes MD-11 pressure test adapters. supersedes T&E 26-20-02 Leak Tester. For DC-10, use with T&E 26-20-04 Adapter Kit.
Douglas
DZZ7355
26-MUL-1470
-505
1470
Leak Tester, Fire Extinguisher System. Pressure source for leak testing firex piping of engines & APU. Includes MD-11 pressure test adapters. supersedes T&E 26-20-02 Leak Tester. For DC-10, use with T&E 26-20-04 Adapter Kit.
Douglas
DZZ7355
26-MUL-1470
-507
1470
Tester, Fire Extinguisher System Leak. Pressure source and plugs for leak testing engine and APU firex piping.
Douglas
DZZ7355
26-MUL-1470
-509
1470
Tester, Fire Extinguisher System Leak. Pressure source and plugs for leak testing engine and APU firex piping.
Douglas
DZZ7355
26-MUL-1470
-511
1470
Tester, Fire Extinguisher System Leak. Pressure source and plugs for leak testing engine and APU firex piping.
Douglas
DZZ7369
32-MUL-1505
-1
1505
Adapter, Anti-Skid Transducer. Spoiler test requires min. 800 RPM drill motor. Anti-skid transducer test requires min. 200 RPM drill motor, or spin adapter by hand. -1 for ship 585 & prior, -501 for ships 586 and subsequent. Used with AII P/N 32-D10-1224.